GL.control
The GL.control system is set-up on two computing units. The user software is strictly separated from the NC software. This ensures its real-time capabilities and offers a comfortable control in the well-known windows environment.
TECHNICAL DETAILS
position set point time | 125 µs |
---|---|
set changing time | < 100 μs |
interpolation accuracy | 0,6 x 10‾⁹ mm |
look ahead | 25000 sets |
transformations | displacement, rotation, RTCP (Rotation Tool Center Point) |
drive interface | SERCOS III |
laser control | position synchronous pulse < 40 nm |
position set point time 125 µs |
---|
set changing time < 100 μs |
interpolation accuracy 0,6 x 10‾⁹ mm |
Look Ahead 25000 sets |
transformations displacement, rotation, RTCP (Rotation Tool Center Point) |
drive interface SERCOS III |
laser control position synchronous pulse < 40 nm |